     Vector network analyzer
     Desk top vector network analyzer
     Portable vector network analyzer
     Calibrator kit、test accessories
     Cable
     Test accessories
     Calibration kit
     University laborotory system
     RF Laboratory measurement system
     Antenna measurement system
     Microwave general-purpose experiment system
     Measurement of ε’and ε’’ for liquids
     Measurement of ε’and ε’’, μ’ and μ’’ of material
     Electromagnetic shield effect analysis measurement
     Broadcasting&TV measurement instruments
     Vector network analyzer
     Field strength measure
     Anti interference bridge
     Differential bridge
     RF EM parametric measurement products
     Measurement of ε’and ε’’ for liquids
     Measurement of ε’and ε’’, μ’ and μ’’ of material
     Electromagnetic shield effect analysis measurement
     Double-sided copper plate εr and Q value
     Measurement of low εr
     Antenna azimuth measurement
     吸波材料反射系數的測試
     RF general-purpose tester
     2011年春季全國高教儀器展
     誠 聘
     誠招各地銷售商
     PNA網絡分析儀的主要性能
     應用示例
     高校射頻實驗及天線方向圖 測試
    PNA Instruments Co.,Ltd 14th floor of Jiangdong North road NO: 301, Nanjing, China Tel: +86-25-86200301 ,-86200340 E-mail:sales@www.omghehe.com
     
    PNA3621P Vector Network Analyzer
     
      Details
     
     Full frequency scan, list scan and point frequency measurement available.
    Capable for transmission measurement (measurement of amplitude vs. frequency characteristics, insertion loss, phase shift, amplifier gain, antenna gain, group delay, antenna azimuth pattern optional), reflection measurement (measure SWR, R.L., complex impedance, reflection phase, electrical length, and Smith Chart display function), time domain fault location function (TDR).
    Transmission measurement has either logarithm-amplitude display or amplitude-phase display; Reflection measurement has LOG display, SWR display, and Smith Chart display.
    5.0” liquid colour display (LCD), serial port output, USB storage disk.
    Portable(light weight, volume small, option built-in lithium battery power supply satiable for RF measurement under special environment).
     
    Application scope and relational properties:
    Widely used in the antenna-feed system test and measure installations of FM, TV, CATV, communications, RADAR etc, and also for the RF microwave education laboratory in the university.
    Optional matched, for 50Ω, 75Ω, 100Ω etc, different characteristic impedance systems.
    Time domain fault location function. It is able to locate a fault in a coaxial cable, with its range: 0-1200 meterprecisely located, a thousandth of full scale
    Configure the correspondingtest accessories (impedance converter and differential bridge…) so as to satisfy the coaxial cable, twin-twist cable, coaxial connector, etc ,the characteristic impedance of transmission lines, loss, delay, phase shift parameters such as test, and is able to detect leakage of RF cables and shield performance.
    Select and prepare corresponding probes capability for the ε measure of such material as the liquids, plane solids, powder, fabric etc.
    When a battery power is built in, it is profitable to high climbing, space narrow, inadmissible or no AC 220V field application. 
     
     
    Main Specifications
    Model
    PNA3621P
    Signal
    source
    Frequency range
    30~3200MHz
    Frequency precision
    ≤10-5
    Frequency resolution
    0.025MHz
    Display
    Insertion loss resolution
    uncertainty
    0.01dB/div
    ± 0.2dB ±4%dB value within 50dB range
    Reflection resolution
    uncertainty
    0.002.
    Small reflection uncertainty is about 0.01(i.e. residual SWR 1.02)
    Phase resolution
    uncertainty
    0.1°.
    Uncertainty about 5°/amplitude
    Characteristic of measurement
    Frequency range
    30~3200MHz
    Group time delay
    1ns40μs
    Time domain fault location
    0~1200m with 7 scale
    Dynamic
    range
    Insertion
    80dB
    RL
    50dB
    Gain
    -2030dB
    Directivity of reflection bridge
    ≥35dB
    R.L. Load
    ≥40dB
    Test channel
    N-Type(single test channel)
    Other
    Power Supply
    50Hz AC220V0.2A fuse 1A
    Overall dimensions(mm)
    150L×320W×133H
    Weight
    5 kg
    Standard accessories
    50Ω N-Type test accessories
    Options accessories
    75Ω N-Type test accessories, twin-wire system measuring kit,
    SW anti-interference bridge test accessories
    TV, FM anti-interference bridgeSMA-Type test accessories,
    Built-in Li-ion battery.
     
     
     
    Copyright reserved Nanjing PNA Instruments Co.,Ltd Mailing address: JiangDong North Road, No.301, 14th floor, Bing Jiang Square, Nanjing 鵝苗價格,百度鵝苗
    備案號:蘇ICP備11058300號 網站建設:南京博賢科技
    国产精品久久久福利app
      <th id="43xjb"></th>
      <rp id="43xjb"></rp>

      <em id="43xjb"><acronym id="43xjb"><input id="43xjb"></input></acronym></em>
    1. <th id="43xjb"></th>
      <rp id="43xjb"><object id="43xjb"></object></rp>
      <th id="43xjb"></th>
      <tbody id="43xjb"><p id="43xjb"></p></tbody>
      <rp id="43xjb"></rp>